30Dec 2024

CRANIOPLASTY: AUTOLOGOUS BONE GRAFT VS TITANIUM MESH

  • Senior Resident, Neurosurgery, RNT Medical College, Udaipur.
  • Senior Resident, Neurosurgery, RNT Medical College, Udaipur.
  • Assistant Professor, Neurosurgery, RNT Medical College, Udaipur.
  • Professor of Neurosurgery, RNT Medical College, Udaipur.
  • Abstract
  • Keywords
  • Cite This Article as
  • Corresponding Author

Background: Cranioplasty (CP) is a neurosurgical procedure performed after decompressive craniectomy using autologous bone graft or various artificial materials. 

Objective: To determine differences in complications between patients who underwent CP using an autologous bone flap versus titanium mesh and to identify significant risk factors for post-CP complications. 

Study Design: Comparative cross-sectional study. 

Methods: A total of 38 patients, 29 males (76.4%) and 9 females (23.6%), were included in this study. All patients underwent cranioplasty with titanium mesh or autologous bone graft. 

Results: The results were compared between autografts and titanium implants. Autologous bone graft was used in 76.3% of the patients and titanium implant was used in 23.7%. Different complications occurred in 5.26% of the patients in both groups, 2.63% in the autologous group and 2.63% in the titanium mesh group respectively. Infection occurred in the surgical site in 5.26% of the patients in both groups (similar). Cranioplasty infection occurred in 2.63% of the patients who underwent autologous transplantation. One patient developed a hematoma in both groups. One patient underwent autologous bone graft removal, and one patient underwent mesh removal. 

Practical Implication: Titanium mesh cranioplasty is an essential procedure for junior neurosurgeons to learn and achieve good results, shorten hospital stay, and save hospital resources. 

Conclusion: Titanium mesh cranioplasty has similar complications to autologous bone cranioplasty.  


[Binit Kedia, Kritesh Goel, Krishna Govind Lodha and Gaurav Jaiswal (2024); CRANIOPLASTY: AUTOLOGOUS BONE GRAFT VS TITANIUM MESH Int. J. of Adv. Res. (Dec). 1101-1104] (ISSN 2320-5407). www.journalijar.com


Dr Binit Kedia

India

DOI:


Article DOI: 10.21474/IJAR01/20118      
DOI URL: https://dx.doi.org/10.21474/IJAR01/20118