28Jan 2021

OPTIMIZATION OF THE DRINKING WATER TREATMENT PROCESS OF A SUGAR PLANT STATION IN COTE DIVOIRE

  • National Polytechnic Institute Felix Houphouet-Boigny, Polytechnic Doctoral School of Yamoussoukro, Laboratory of Industrial Processes, Synthesis, Environment and New Energies. BP 1083 Yamoussoukro, Cote dIvoire.
  • Institut National Polytechnique Houphouet-Boigny, Department of Chemical and Agribusiness Engineering, Laboratory of Industrial Processes, Synthesis, Environment and New Energies (LAPISEN), BP 1083 Yamoussoukro, Cote dIvoire.
  • National Polytechnic Institute Felix Houphouet-Boigny, Higher School of Industry (ESI) of Yamoussoukro.BP 1083.
  • Abstract
  • Keywords
  • Cite This Article as
  • Corresponding Author

This article presents an optimization of the drinking water treatment process at the SUCRIVOIRE treatment station. The objective is to optimize the coagulation and flocculation process (fundamental process of the treatment of said plant)by determining the optimal dosages of the products injected and then proposes a program for calculating the optimal dose of coagulant in order to automatically determine the optimal dose of the latter according to the raw water quality. This contribution has the advantage of saving the user from any calculations the latter simply enters the characteristics of the raw effluent using the physical interface of the program in order to obtain the optimum corresponding coagulant concentration. For the determination of the optimal coagulant doses, we performed Jar-Test flocculation tests in the laboratory over a period of three months. The results made it possible to set up a polynomial regression model of the optimal dose of alumina sulfate as a function of the raw water parameters. A program for calculating the optimal dose of coagulant was carried out on Visual Basic. The optimal doses of coagulant obtained vary from 25, 35, 40 and 45 mg/l depending on the characteristics of the raw effluent. The model obtained is: . Finally, verification tests were carried out using this model on the process. The results obtained meet the WHO drinkability standards for all parameters for a settling time of two hours.   


[Konan Lopez Kouame, Nogbou Emmanuel Assidjo and Andre Kone Ariban (2021); OPTIMIZATION OF THE DRINKING WATER TREATMENT PROCESS OF A SUGAR PLANT STATION IN COTE DIVOIRE Int. J. of Adv. Res. 9 (Jan). 512-524] (ISSN 2320-5407). www.journalijar.com


Konan Lopez KOUAME
National Polytechnic Institute Félix Houphouët-Boigny, Polytechnic Doctoral School of Yamoussoukro, Laboratory of Industrial Processes, Synthesis, Environment and New Energies. BP 1083 Yamoussoukro, Côte d'Ivoire
Cote d

DOI:


Article DOI: 10.21474/IJAR01/12321      
DOI URL: https://dx.doi.org/10.21474/IJAR01/12321