Background: Evaluation of range of motion is integral part of assessment of musculoskeletal system. Range of motion is an essential outcome measure for any orthopedic management protocol. A new technology is developed to measure range of motion by using mobile phones. The objective of this study is to determine intra and inter-rater reliability of mobile device goniometer goniometer records in measuring knee flexion range of motion. Objectives : To find out intra and inter rater reliability of goniometer records application. Material and Methods: 100 students of physiotherapy aged between 19-25 years. Outcome Measure:- Range of motion is the main outcome measure for this study. Result:- 23 males and 77 females within normal body mass index participated. Mean age of participants was 20.39 years .by using student?s unpaired t test intra rater reliability for goniometer records application was high & inter rater reliability was moderate to high. ( p<0.05). Conclusion: Goniometer Records application has high intra-rater and inter-rater reliability was moderate to high..this device can be used to assess range of motion of knee joint.
- Brosseau L, Balmer S, Tousignant M , et al.?Intra- and intertester reliability and criterion validity of the parallelogram and universal goniometers for measuring maximum active knee flexion and extension of patients with knee restrictions. Arch Phys Med Rehabil 2001; 82 vol. (3) pg no. 396-402.
- Milanese S, Gordon S, Buettner P , et al.?Reliability and concurrent validity of??? knee angle measurement: smart phone app versus universal goniometer used by experienced and novice clinicians. Man Ther 2014; 19 vol .(6)pg no. 569-574
- Ritter MA, Lutgring JD, Davis KE, Berend ME, Pierson JL, Meneghini RM.?The role of flexion contracture on outcomes in primary total knee arthroplasty. J Arthroplasty 2007; vol.22 (8) pg no. 1092-1096
- Piriyaprasarth P, Morris ME, Winter A, Bialocerkowski AE.?The reliability of knee joint position testing using electro goniometry. BMC MusculoskeletDisord 2008; vol.9: 6
- Boone DC, Azen SP, Lin CM, Spence C, Baron C, Lee L.?Reliability of goniometric measurements. Phys Ther 1978; vol. 58 (11) pg no. 1355-1360
- Bedekar N, SuryawanshiM,RairikarS,ShyamA.Inter and intra rater reliability of mobile device goniometer in measuring lumbar flexion range of motion. J Back Musculoskeletal rehab.2014; vol 27(2): pg no.161-6.
- Keogh JW, Cox A, Anderson S, Liew B, Olsen A, Schram B, Furness J. Reliability and validity of clinically accessible smartphone applications to measure joint range of motion: A systematic review. PloS one. 2019;14(5).
- Pourahmadi MR, Taghipour M, Jannati E, Mohseni-Bandpei MA, Takamjani IE, Rajabzadeh F. Reliability and validity of an iPhone? application for the measurement of lumbar spine flexion and extension range of motion. PeerJ. 2016 Aug 23;4:e2355.
- Bovens AM, van Baak MA, Vrencken JG, Wijnen JA, Verstappen FT.?Variability and reliability of joint measurements. Am J Sports Med 1990; vol. 18 (1)pg no. 58-63
- Gajdosik, R., Bohannon, R. Clinical measurement of range of motion: Review of goniomtery emphasizing reliabilty and validity. Physical Therapy. 1987;67(12):1867-72 (6).
- Milanese, S., Gordon, S., Buettner, P., Flavell, C., Ruston, S., Coe, D., O'Sullivan, W., McCormack, S. Reliability and concurrent validity of knee angle measurement: smartphone app versus universal goniometer used by experienced and novice clinicians. Man Ther. 2014;19(6):569-74.
- Susan Reid PhD,? BAppSc (Phty), MMedSc? (Phty), GradDip (ManipPhty), BPharm *,Brigitte Egan BPhty (Hons) The validity and reliability of Dr Goniometer, a smartphone application, for measuring forearm supination 21 December 2017
- Jones, A., Sealey, R., Crowe, M., Gordon, S. Concurrent validity and reliability of the simple goniometer iPhone app compared with Universal Goniometer. Physiotherapy Theory Pract. 2014;30(7):512-6.
- Mullaney MJ, McHugh MP, Johnson CP, Tyler TF. Reliability of shoulder range of motion comparing?? a goniometer to a digital level. Physiotherapy Theory Pract. 2010;26:327?333. Pub Med doi:10.3109/09593980903094230
- Goodwin J, Clark C, Deakes J, Burdon D, Lawrence Clinical method? of goniometry: comparative study. DisabilRehabil. 1992;14:10?15.
- Charlton PC, Mentiplay BF, Pua YH, Clark RA. Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion. Journal of Science and Medicine in Sport. 2015 May 1;18(3):262-7
- Tousignant-Laflamme Y, Boutin N, Dion AM, Vallee C Reliability and criterion validity of two applications of? the iPhone to measure cervical range of motion in healthy? J NeuroengRehabil. 2013; 10:69.
- Alberto Melian Ortiz, Sof?a Laguarta Val and David Varillas Delgado. Reliability and Concurrent Validity of the Goniometer-Pro App vs a Universal Goniometer in determining Passive Flexion of Knee.?International Journal of Computer Applications173(1):30-34, September 2017.
- http://itunes.apple.com/us/app/goniometer/id406942245?mt=8/https://play.google.com/store/apps/details?id=com.scriptlanes.goniometer&hl=en.
[Payal Rangarej and Pradeep Borkar (PT) (2020); RELIABILITY OF GONIOMETER RECORDS APPLICATION FOR MEASURING RANGE OF MOTION OF KNEE JOINT IN NORMAL HEALTHY INDIVIDUAL Int. J. of Adv. Res. 8 (Jan). 978-982] (ISSN 2320-5407). www.journalijar.com
Intern, Dr. A.P.J. Abdul Kalam College of Physiotherapy, Loni, Maharashtra, India